background image

B-5

OPERATION

B-5

RANGER 8

Summary of Welding Processes

CONTROL ELECTRODE

CABLE IDLE WHEN NOT TO START

PROCESS USED MODE WELDING WELDING

STICK

No

AUTO

Hot

Touch electrode to work.
Welding starts immediately
and engine goes to high
idle.

TIG/K7930-1/K938-1,

Yes

HIGH

Cold

Press Amptrol, contactor

K936-( ) /K892-1

closes, welding

(WITH AMPTROL)

starts immediately.

WIRE FEED, LN-25 WITH

No

AUTO

Cold

Press gun trigger, LN-25

INTERNAL CONTACTOR

contactor closes. Welding
starts immediately and
engine goes to high idle.
NOTE: Output Control
must be set above “3”.

WIRE FEED, LN-7 WITH

Yes

HIGH

Cold

Press gun trigger,

K240 CONTACTOR KIT

contactor closes. Welding
starts immediately.

Advertising