RECOMMENDED EQUIPMENT

STICK

K702 Accessory Kit which includes:

• Electrode holder and cable
• Work clamp and cable
• Headshield

K857 Remote Control Kit is optional for remote
current control.

WIRE FEED

LN-25 (K428 or K446) with K624-1 42 Volt Remote
Output Control Module - Requires K626-xx Control
Cable. Provides "cold" electrode until gun trigger is
pressed. Voltage control is at the feeder. K446
LN-25 includes gas solenoid.

LN-25 (K449) Includes internal contactor for across
the arc operation (no control cable). Provides "cold"
electrode until gun trigger is pressed. Includes gas
solenoid. K444-1 Remote Voltage Control Kit is
required for voltage control at the feeder.

LN-742 (K617-1 or K618-1) or LN-742H (K617-2 or
K618-2), requires K619-xx Input Cable Assembly.
Provides "cold" electrode until gun trigger is pressed.
Includes gas solenoid. K589-1 Remote Control Kit
connects to the LN-742 to provide remote voltage and
wire speed control or K857 Remote Voltage Control
Kit connects to the Ranger 9 for voltage control at the
feeder.

LN-7 (K521) or LN-7 GMA (K440), requires K584-xx
Input Cable Assembly. Provides "cold" electrode until
gun trigger is pressed. K440 LN-7 GMA included gas
solenoid. K8567 Remote Voltage Control Kit is
required for voltage control at the feeder. Ranger 9
must be operated at "HIGH" idle.

Magnum Gun is required for gas-shielded welding.
Innershield Gun is required for gas-less welding.

TIG

Magnum™ TIG Torch
Magnum Parts Kit and Argon gas
K930-1 TIG Module
K936-1 Control Cable

Optional:

K939-1 TIG Module Docking Kit
K963 Hand Amptrol™
K870 Foot Amptrol
K814 Arc Start Switch