Output system trouble, Cause, What to do – Lincoln Electric IM511 RANGER 9 User Manual

Page 29

Advertising
background image

OUTPUT SYSTEM

TROUBLE

E. Contactor does not pull in when

scratch starting when engine
goes to high idle.

F. Contactor does not pull in when

using a wire feeder with a control
cable plugged into amphenol.

G. Contactor does not drop out.

CAUSE

1. Welding terminal switch in wrong

position.

2. Faulty wiring in contactor circuit.

3. Faulty remote switch S6.

4. Faulty contactor.

5. Faulty P.C. Board PCB1.

1. “WELDING TERMINALS” switch

in wrong position.

2. Faulty wiring in contactor circuit.

3. Faulty amphenol or bypass P.C.

Board PCB2.

4. Faulty contactor.

5. Faulty P.C. Board PCB1.

6. Faulty control cable from wire

feeder or amphenol.

7. Faulty wire feeder.

1. Faulty wiring.

2. Faulty amphenol or bypass P.C.

Board PCB2.

3. Faulty contactor.
4. Faulty P.C. Board PCB1.

WHAT TO DO

1. Place switch S6 in “Always On”

position.

2. Check for broken leads #224C,

#232A, and #224.

3. Check switch and leads #247,

and #250.

4. Replace contactor with known

good one.

5. Replace P.C. Board with known

good one.

1. Place switch S6 in “REMOTELY

CONTROLLED” position.

2. Check for broken leads #224,

#224C & #232A.

3. Refer to wiring diagram and

check related leads (#2 and #4).

4. Replace contactor with known

good one.

5. Replace P.C. Board with known

good one.

6. Replace.

7. Repair or replace.

1. Check that lead #232 is not

grounded.

2. Look for shorts to ground. Repair

or replace.

3. Replace with known good one.
4. Replace with known good one.

-27 -