Chapter 8

126

Seed Hawk® Viper Pro™ Installation & Operation Manual

To modify the feature or alarm settings for the above features, touch within the feature settings area on the
CAN Controller Status screen.

Note:

Before changing any of the feature or alarm settings, be sure to select the correct product node or
control channel by touching the corresponding radio button displayed at the top of the feature
settings area.

Node Settings Screen (Page 1)

Touch within the Feature Settings area to view the first screen of settings for the selected product node or
control channel.

Note:

Touch the Next button to access additional alarm and feature settings for the selected product
node or control channel.

Off Rate %. The off rate percent value sets the allowable difference between the target and actual product
application rates. If a non-zero value is entered for this setting and the difference between target and actual
rate exceeds the set value for longer than five seconds, the Viper Pro will display an off rate alarm. Enter a
value of zero to disable the off rate alarm.

Low Limit. This setting is not used with Seed Hawk air cart ground drive systems. The low limit default setting
is zero and should not be altered.

Low Tank. This setting is not used with Seed Hawk air cart ground drive systems. The low tank default setting
is zero and should not be altered.

Status Screen Example

(Products 1-3)