ATM I

NSTALLATION

FOR

A

CCESSIBILITY

305

Clear Floor or Ground Space

305.1

General. Clear floor or ground space shall comply with 305.

305.2

Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or
ground space shall comply with 302. Changes in level are not permitted.

EXCEPTION: Slopes not steeper than 1:48 shall be permitted.

305.3

Size. The clear floor or ground space shall be 30 inches (760 mm) mini-
mum by 48 inches (1220 mm) minimum.

305.4

Knee and Toe Clearance. Unless otherwise specified, clear floor or
ground space shall be permitted to include knee and toe clearance com-
plying with 306.

305.5

Position. Unless otherwise specified, clear floor or ground space shall be
positioned for either forward or parallel approach to an element.

305.6

Approach. One full unobstructed side of the clear floor or ground space
shall adjoin an accessible route or adjoin another clear floor or ground
space.

Figure 305.3 Clear Floor or Ground Space

Figure 305.5 Position of Clear Floor or Ground Space