D

ETERMINE

IF

U

NIT

NEEDS

A

P

LINTH

Triton Systems offers two (2) metal-constructed optional plinths w/leveling
feet. A “plinth” is a platform on which the ATM rests or is secured. A plinth
enables the ATM to be installed at the required height through the wall. The
plinths come in 2 heights: 2-3/8” (61mm - shown below) and 4-3/4” (122 mm).
You can raise the unit by a fixed amount (2-3/8"or 4-3/4") and still be able to
adjust up using the plinths leveling feet. To determine if you need to order a
plinth with your unit, a few measurements will be needed at the site.

For sites that currently have a wall opening:

1.

Measure from the bottom of opening to inside floor (Figure 1).

2.

Cabinet dimensions are 26-1/2" from bottom of sleeve to base of cabinet
(Figure 2).

3.

Subtract the difference to determine if a plinth is needed or what size plinth
to order or build. If difference is less than 2-3/8"(for example), you may
construct your own to fit. (Caution: The leveling feet on the cabinet itself
should not be used to raise the unit significantly)

Figure 1. Determine height of

opening to inside floor.

Leveling feet

Wall tab

Cabinet mounting holes

Floor anchor holes

Cabinet mounting holes

Figure 2. Height of cabinet base to

bottom of sleeve (28").