Activate Mode of Choice

To activate and select a printer function:

1. Select the PRINTER SCR display using the UP key.
2. Press and hold ENT until the FEM-03 displays the “PRINTER ON” prompt.
3. The unit first offers a NO response. To activate a print function, use the SEL key to toggle the

response to YES and press ENT. The unit now prompts for the mode selection.

4. Use the SEL key to select the print operation, and press ENT to initiate the print operation.

PRINTER Hardware Specification/Connection

The factory has tested printer operation with the following combination of equipment:

FEM-03 all models (any software version after/including rev. 1.06)

SXP-320A RS232 serial to parallel converter (JAMECO Catalog Part Number 116935)

HP Deskjet 672 C

The SXP-320A parallel connector plugs directly into the printer, and the serial connector is a 25-pin
female D-sub. Connections between FEM-03 and SXP-320A are as follows:

FEM-03 TX output ( terminal DN 4) connects to pin 2 (RX input) on the 25 pin D-sub.

FEM-03 Common ( terminal DN 6) connects to pin 7 (comm./gnd) on the 25 pin D-sub.

The SPX-320A must be configured as follows:

Baud rate = 9600 (or 19200, 38400, or 57600) Must match the FEM-03 baud rate!

Handshake = XON/XOFF

Data Length = 8 Bits (1 stop bit automatically)

Parity = None

Data direction = S P (serial to parallel)

Configure the FEM-03 baud rate as follows:

1. Use the UP key to select the SERIAL COM display.

2. Press and hold ENT to access the parameters and verify or select a baud rate matching

the SXP-320A converter (9600 recommended). Must match the SXP-320A baud rate!