Caution – HT instruments HT7052 User Manual

Page 20

Advertising
background image

HT7052

EN - 18

6.4 VOLTAGE

MEASUREMENT

CAUTION

Maximum input for DC or AC voltage is 600V. Do not attempt to take any
voltage measurement that exceeds the limits. Exceeding the limits could
cause electrical shock and damage the instrument


1. Switch on the instrument by pressing the ON/OFF key
2. Select with arrow keys  or  the item “VOLTAGE” on main menu and confirm with

SELECT key. The screen of Fig. 13 is shown by the meter

Fig. 13: Initial screen of voltage measure

Fig. 14: Screen of measured value


3. Connect the red part of the Test lead 1 or Test leads 2 (see § 4.2) to the +OUTPUT

input and the black part of the Test leads 2 (see § 4.2) to the –OUTPUT input

4. Connect the tip of Test lead 1 or Test leads 2 (positive) and the black cable of Test

leads 2 (negative) to the object on test respect the polarities for DC voltage
measurement (see Fig. 15)

Fig. 15: Connection of meter for voltage measurement

5. Press START/STOP key to activate the measurement in continuous mode
6. Press again the START/STOP to stop the measurement. The result of test is shown at

display (see Fig. 14)

7. For saving the result see § 7