̶ 26 ̶

 ② Slide the terminal cover to the right to disclose the OUTPUT

terminal and insert the output plug into the terminal. Make
connection to the recording device.

 ③ When the plug is inserted into the output terminal, auto-range

function is cleared.

  Set the range depending on the state of Data Hold Switch.

Data Hold Switch OFF 400A range

Data Hold Switch ON 2000A range

Note: After measurement, be sure to return Data Hold Switch to OFF

position.

 ④ Set the function selector switch to the desired position (ACA or

DCA) and follow appropriate measurement instructions.

NOTE
 ● During current measurement, keep the transformer jaws fully

closed. Otherwise, accurate measurement cannot be made.
The maximum measurable conductor size is approx. 55mm in
diameter.

 ● Zero adjustment is not necessary on AC current range.
 ● On DC current range, the Zero Adjust/Reset button may not

completely zero adjust the output voltage from the OUTPUT
terminal. In this case, make zero adjustment on the recording device.

 ● Connecting the plug to the OUTPUT terminal disables the Auto-

power-off function. The function is enabled on removing the plug
from the terminal.