3.Specifications

● Measuring Ranges and Accuracy (at 23 ℃ ± 5 ℃ , relative

humidity75% or less)

AC Current  (RMS value detection, Auto-range)

Range

Display range

Allowable input

Accuracy※

(Frequency)

400A

0.0∼420.0A

0.0∼1700Arms

±1.3%rdg±3dgt

(45∼66Hz)

±2.0%rdg±5dgt

(20Hz∼1kHz)

2000A

150∼2100A

1700∼2000Arms

(3000Apeak or less)

±2.3%rdg±3dgt

(45∼66Hz)

※ For non-sinusoidal waveforms, add ±(1.5% of full scale), for Crest

factor<3.

※4 counts or less is corrected to 0

DC Current , Auto-range

Range

Display range

Allowable input

Accuracy

400A

±0.0∼420.0A

0.0∼±2000A

±1.3%rdg±2dgt

After zero adjustments

2000A

±150∼2100A

AC Voltage  (RMS value detection, Auto-range)

Range

Display range

Allowable input

Accuracy※

(Frequency)

40V

0.00∼42.00V

0.00∼750Vrms

(1200Vpeak or less)

±1.0%rdg±2dgt

(45∼66Hz)

±1.5%rdg±5dgt

(20Hz∼1kHz)

400V

15.0∼420.0V

750V

150∼788V

※Input Impedance:approx. 2MΩ <200pF
※ For non-sinusoidal waveforms, add ±(1.5% of full scale), for Crest

factor<3.

※4 counts or less is corrected to 0