Section 4 Sample Measurement

4-2.

4.1 Evaluation Measurement for the Receiver

The evaluation measurement procedure for the W-CDMA receiver is de-
scribed below.

Setup

Measurement procedure
[1] Set the frequency for the wanted signal source to the testing fre-

quency.

[2] Set the output level of the unit to the proper level for the input con-

nector of the receiver.

[3] Set the unit to W-CDMA modulation.
[4] Set the modulation parameter of the unit so that the receiver can re-

ceive the signal.

[5] Set the frequency for the noise signal source to that set in Step [1].
[6] Set the noise bandwidth for the unit to that wide enough for the

wanted signal.

[7] Set the calculated bandwidth for the unit to that for the wanted sig-

nal.

[8] Set the output level for the unit to the optimum level for the input

connector of the receiver. However, it should be higher by the noise
band calculation level.

[9] Measure the reception sensitivity of the receiver.

MG3681A + MU368040A + MX368041A/B

Two-signal coupler

Receiver

Wanted signal source

Noise signal source

MG3681A + MU368060A

MG3681A

Digital Modulation
Signal Generator
250kHz -3GHz
3-6GHz (Option)

Cancel

Set

RPP Reset

Edit

Cursor

RF Output

Modulation

Function

On

Stby

Panel Lock

Local

Remote

Contrast

Preset

Knob Hold

Step

Resolution

Off

>○<

On

Frequency

Level

Memory

Digital Mod

Analog Mod

Config

%

Recall

Save

dB

Hz / fW

deg / µV

-/+

0

BS

CE

Shift

C

B

A

F

E

Screen Copy

D

Display Off/On

3

TTL

TTL

5

TTL

4

TTL

2

TTL

1

Digital Input

I/Q Input / I/Q Output

I / Wide AM

50Ω

50Ω

Q

Output

Input

I/Q Output

Pulse

TTL

AF

600Ω

600Ω

FM/φM

600Ω

AM

50Ω

Q

50Ω

I

RF

50Ω

!

Reverse Power
50W Max≦1GHz
25W Max>1GHz
±

50V DC Max

kHz/nW

rad / mV

3

2

1

MHz/mW

ms / V

6

5

4

GHz/dBm

s /dBµV

9

8

7

Analog

Digital

F1

F2

F3

F4

F5

F6

Freq

3

000

.

000

000

00

MHz

Level

-123

.

15

dBm

IQ Input

Symbol Clk

Clock

Data

Invrement

Step Value

Current

Frequency

Relative

On Off

Offset

On Off

Offset

Value

Frequency

Modulation Mode : I,Q Source : [Int]

System : [PDC ]


Mod : π/4 DQPSK Bit Rate : 42.0 kbit/s

Filter : [RNYQ] α=0.50


Burst : [On]

Pattern : [UP TCH ]

Trigger : [Int]

Slot 0 Slot 1 Slot 2


UP TCH

△ △

MG3681A

Digital Modulation
Signal Generator
250kHz -3GHz
3-6GHz (Option)

Cancel

Set

RPP Reset

Edit

Cursor

RF Output

Modulation

Function

On

Stby

Panel Lock

Local

Remote

Contrast

Preset

Knob Hold

Step

Resolution

Off

>○<

On

Frequency

Level

Memory

Digital Mod

Analog Mod

Config

%

Recall

Save

dB

Hz / fW

deg / µV

-/+

0

BS

CE

Shift

C

B

A

F

E

Screen Copy

D

Display Off/On

3

TTL

TTL

5

TTL

4

TTL

2

TTL

1

Digital Input

I/Q Input / I/Q Output

I / Wide AM

50Ω

50Ω

Q

Output

Input

I/Q Output

Pulse

TTL

AF

600Ω

600Ω

FM/φM

600Ω

AM

50Ω

Q

50Ω

I

RF

50Ω

!

Reverse Power
50W Max≦1GHz
25W Max>1GHz
±

50V DC Max

kHz/nW

rad / mV

3

2

1

MHz/mW

ms / V

6

5

4

GHz/dBm

s /dBµV

9

8

7

Analog

Digital

F1

F2

F3

F4

F5

F6

Freq

3

000

.

000

000

00

MHz

Level

-123

.

15

dBm

IQ Input

Symbol Clk

Clock

Data

Invrement

Step Value

Current

Frequency

Relative

On Off

Offset

On Off

Offset

Value

Frequency

Modulation Mode : I,Q Source : [Int]

System : [PDC ]


Mod : π/4 DQPSK Bit Rate : 42.0 kbit/s

Filter : [RNYQ] α=0.50


Burst : [On]

Pattern : [UP TCH ]

Trigger : [Int]

Slot 0 Slot 1 Slot 2


UP TCH

△ △

Advertising