― 14 ―

NOTE

● During current measurement, keep the transformer jaws fully

closed. Otherwise, accurate measurement cannot be made. The
maximum measurable conductor size is approx. 55mm in
diameter.

● When the current flows from the upside (the display side) to the

underside of the instrument, the reading is indicated positive.

● The Zero Adjust/Reset button may not completely zero adjust the

output voltage from the OUTPUT terminal. In this case, make zero
adjustment on the recording device.

● Turing the function selector switch to a position other than DCA

cancels the zero adjustment .

6−2 AC Current Measurement

DANGER

●Never use the instrument on a circuit above 750VAC. This may

cause electrical shock hazard and damage to the instrument or the
circuit under test.

●Do not make measurement with the test leads plugged into the

instrument.

●Do not make measurement with the battery compartment cover

removed.

●Keep your fingers and hands behind the barrier during measurement.

Correct

Wrong