DANGER

●Never use the instrument on a circuit above 750VAC/1000VDC.

This may cause electrical shock hazard and damage to the
instrument or the circuit under test.

●Do not make measurement with the battery compartment cover

removed.

●Do not make measurement with the test leads plugged into the

instrument.

●Keep your fingers and hands behind the barrier during measurement.

①The PEAK mode is available on DCA, ACA, DCV and DCA ranges.

Set the function selector switch to the desired position.
Note:Only on DCA range, press the Zero Adjust/Reset button for

about one second to zero adjust the reading with the
transformer jaws closed.

②Press the mode selector button twice to enter from the normal mode

to the PEAK mode. "PEAK" should be shown on the display.

③Follow instructions for DCA, ACA, DCV or ACV measurement.

Note:For accurate reading, press the Zero Adjust/Reset button to reset

the reading after clamping onto the conductor or making test lead
connections to the circuit under test. Then, proceed to
measurement.

Vp

INPUT Current

Vp/

2

Peak Hold