Danger – KYORITSU 2009A User Manual

Page 17

Advertising
background image

― 15 ―

①Set the function selector switch to the "∼A" position. “AC" should

be shown on the upper left corner of the display.

②Press the trigger to open the transformer jaws and clamp them onto

a single conductor and take the reading on the display. The most
accurate reading will be obtained by keeping the conductor at the
center of the transformer jaws.

NOTE

● During current measurement, keep the transformer jaws fully

closed. Otherwise, accurate measurements cannot be taken.
Maximum conductor size is 55㎜ in diameter.

● Zero adjustment is not necessary in AC current measurement.
● When the current under test measures 3% of the full scale or less,

or the frequency of the current is low, "LoHz" is indicated on the
display.

6−3 DC Voltage Measurement

DANGER

●Never use the instrument on a circuit above 1000VDC. This may

cause electrical shock hazard and damage to the instrument or the
circuit under test.

●Do not make measurement with the battery compartment cover

removed.

●Keep your fingers and hands behind the barrier during measurement.

Advertising