Connector pin outs, Troubleshooting – Revo RE8/16DVR1 User Manual

Page 75

Advertising
background image

Digital Video Recorder

67


Connector Pin Outs

I/O Connector Pin Outs

AI (1 to 16)

Alarm Inputs 1 to 16

GND

Chassis Ground (6 connectors)

NC

Relay Alarm Output (Normally Closed)

COM

Relay Common

NO

Relay Alarm Output (Normally Open)

ARI

Alarm Reset In

RS485

Connector Pin Outs

Master Unit

Slave Unit

+

 To 

TX+/ RX+

 To 

TX-/ RX-


Troubleshooting

Problem

Possible Solution

No Power

 Check power cord connections.
 Confirm that there is power at the outlet.

No Live Video

 Check camera video cable and connections.
 Check monitor video cable and connections.
 Confirm that the camera has power.
 Check camera lens settings.

Live Video Very Bright

If a cable is attached to the “Loop” connector, make certain it is connected to a
properly terminated device.

DVR has stopped recording

If hard disk drive is full, you will either need to delete video or set the DVR to the
Overwrite Mode.

The icon displays,
however, the DVR is not
recording.

When the DVR is in the Pre-Event recording mode, the yellow and display

when there is no event, and the DVR is not recording. The red and display

when any event occurs and the DVR starts recording.