AMX RADIA Lighting Programming

48

RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules

Phase Query (NEW)

This function queries the current state of the phase detection system. Phase zero-crossing detection occurs at
all times.



In the presence of a phase/zero-cross error, the AxLink LED will blink very fast (more than 10Hz)
and all string responses with strings that give responses will be "PHASE ERROR!".



The response will be an incoming COMMAND to the master.

Phase Query

Command:

?Y

Response:

Y-<pass/fail> 1<state1> 2A<state2A> 2B<state2B> 3<state3>

The <pass/fail> item will either be 'OK' or 'FAIL' to indicate an overall condition.

The <state> items are phase specific to indicate which phase is failing.

The <state> will either be 'Y' for okay or 'N' failure.

Examples:

SEND_COMMAND Radia,'?Y'

check phase status

Response: 'Y-OK 1Y 2AN 2BN 3N'

Good response

SEND_COMMAND Radia,'?Y'

check phase status

Response: 'Y-FAIL 1Y 2AN 2BN 3Y' Fail on 2A and 2B