Cooling only fixed capacities, Condensing units blucube, Condensing units – Airedale BluCube 10-48kW User Manual

Page 35

Advertising
background image







Condensing Units

BluCube

Condensing Units

35

Technical Manual : 7206188 V1.6.0_07_2014


Cooling Only Fixed Capacities

Ambient (°C)

25

30

35

40

45

Unit

TEvap

(°C)

Output

(kW)

Input

(kW)

Output

(kW)

Input

(kW)

Output

(kW)

Input

(kW)

Output

(kW)

Input

(kW)

Output

(kW)

Input

(kW)

CUR092V16-1CO-0

-5

9.6

3.8

9.6

3.8

9.2

4.0

8.6

4.4

8.0

4.8

0

11.5

3.8

11.5

3.8

11.0

4.0

10.3

4.4

9.6

4.9

5

13.8

3.8

13.7

3.7

13.0

4.1

12.2

4.5

11.5

4.9

7

14.8

3.8

14.7

3.7

13.8

4.1

13.0

4.5

12.2

4.9

10

16.4

3.8

16.2

3.7

15.2

4.1

14.3

4.5

13.5

5.0

CUR092V20-1CO-0

-5

14.7

5.5

14.5

5.5

13.7

5.9

12.7

6.4

11.7

6.9

0

17.6

5.4

17.2

5.6

16.2

6.0

15.2

6.5

14.1

7.0

5

21.1

5.3

20.2

5.6

19.1

6.1

17.9

6.6

16.8

7.2

7

22.6

5.3

21.5

5.7

20.3

6.2

19.1

6.7

17.9

7.2

10

25.0

5.3

23.6

5.7

22.2

6.2

20.9

6.7

19.6

7.3

CUR092V25-1CO-0

-5

19.2

6.8

18.6

7.1

17.5

7.7

16.4

8.4

N/A

N/A

0

23.2

6.9

22.1

7.4

20.9

8.0

19.5

8.7

18.0

9.5

5

27.6

7.1

26.1

7.7

24.5

8.3

22.8

9.0

21.0

9.8

7

29.4

7.2

27.7

7.8

26.0

8.4

24.2

9.1

22.3

9.9

10

32.1

7.5

30.3

8.0

28.4

8.7

26.5

9.3

24.3

10.1

CUR092V29-1CO-0

-5

21.8

7.5

20.7

8.0

19.3

8.7

17.9

9.5

N/A

N/A

0

26.1

7.6

24.5

8.3

22.9

9.0

21.2

9.9

19.4

10.8

5

30.6

8.0

28.8

8.6

26.9

9.4

24.9

10.2

22.8

11.1

7

32.5

8.1

30.6

8.8

28.6

9.5

26.5

10.4

24.3

11.3

10

35.4

8.3

33.4

9.0

31.2

9.8

28.9

10.6

26.5

11.5

CUR122V35-1CO-0

-5

28.5

9.4

27.9

12.0

26.1

13.0

24.2

14.1

22.2

15.3

0

34.3

9.8

33.1

12.3

31.0

13.3

28.8

14.4

26.4

15.6

5

41.0

11.2

38.9

12.7

36.5

13.6

33.9

14.7

31.1

15.9

7

43.7

11.9

41.3

12.8

38.8

13.8

36.1

14.8

33.1

16.1

10

47.8

12.2

45.2

13.0

42.4

14.0

39.5

15.1

36.3

16.3

CUR122V40-1CO-0

-5

32.7

11.0

31.6

13.6

29.6

14.5

27.6

15.6

N/A

N/A

0

39.3

12.5

37.3

14.0

35.0

15.0

32.6

16.1

30.0

17.3

5

46.2

13.6

43.6

14.5

40.9

15.5

38.1

16.6

35.0

17.9

7

49.0

13.8

46.3

14.8

43.4

15.7

40.4

16.9

37.2

18.1

10

53.5

14.2

50.5

15.1

47.4

16.1

44.1

17.2

40.6

18.5

Notes:
1

Output kW refers to the compressor duty.

2

Input kW refers to the compressor and fan input power only.

All performance data is supplied in accordance with BS EN 14511-1:2013

Advertising