ORION® Gas Endpoints, Integral Endpoint for American® Commercial Gas Meters

2 When mounting an ORION integral endpoint to a gas meter make sure the endpoint drive pawl engages the gas meter

drive pawl These two drive pawls must mate without causing any binding or potential for disengagement Test to ensure

the pawls are engaged and moving freely

MPORTANT

I

Placing endpoint on meter incorrectly may damage the output seal of the gas meter.

Endpoint drive pawl

Meter drive pawl

Figure 10: Mate endpoint and meter drive pawls

3 Be sure the gas INLET markings are on the same side of the meter and the lens faces forward See

Figure 11

Gas inlet markings

Lens facing forward

to front of meter

Figure 11: Inlet markings on same side of meter

4 Place the American index and cover plate (removed earlier) back on the ORION integral endpoint Place it so the text

TURBINE FRONT FLOW AL-600, AL-1000, AL-1400, AL-2300, and AL-5000 (or other such text) faces the front and the index

hole is centered around the endpoint drive pawl

Place the index drive pawl perpendicular to the endpoint drive pawl

Index drive

pawl

Endpoint

drive pawl

Figure 12: Place index and cover plate on endpoint