Install the orion integral endpoint and – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 9

Advertising
background image

Installation Manual

ORION INTEGRAL ENDPOINT KIT FOR AMERICAN COMMERCIAL DIAPHRAGM

AND TURBINE METER WITH WIRE SEAL SECURITY SCREW

ORION integral

endpoint

4 screws

2 washers

2 large tamper

plugs

2 seal caps

2 small

tamper plugs

Figure 8: ORION integral endpoint kit

OTEE:

N

The screws provided in this installation kit are not drilled for wire seals Therefore, the wire seal is replaced with plastic

seal caps provided in the kit

INSTALL THE ORION INTEGRAL ENDPOINT AND AMERICAN COVER PLATE

Use care when handling the ORION integral endpoint to insure the drive pawl is not subjected to any physical abuse Abuse

may cause this spindle to become bent, misaligned or otherwise inoperative
When attaching an ORION integral endpoint to a gas meter make sure it mounts securely to the meter
1 Place the ORION integral endpoint on top of the gas meter where the index and index cover plate were previously

removed Place the endpoint drive pawl spindle so it is perpendicular to the meter drive pawl

Drive pawl

spindle

Figure 9: Endpoint drive pawl placement

Page 9

July 2014

Advertising
This manual is related to the following products: