Adding additional labels, Adding additional labels 7 – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 7

Advertising
background image

Installation Manual

AMERICAN COMMERCIAL DIAPHRAGM AND TURBINE METERS WITH WIRE

SEAL SECURITY SCREW

Index and Index Cover Plate Removal from American Meter with Seal Security Screw

1 Remove the wire security seal from the index cover mounting screw

Figure 1: Wire security seal

2 Use a large screwdriver to remove the four (4) 18-8 index cover mounting plate screws and American index

Discard the four screws

Figure 2: Remove screws on index cover mounting plate

3 Remove the American index and mounting plate

Figure 3: Remove index mounting plate