Electrical, Operation, Maintenance – Blue Angel Pumps SBS100 User Manual

Page 5: Continued)

Advertising
background image

5

Electrical

(Continued)

7b). The ground conductor must not
be smaller than the circuit conductors
supplying the motor.

Disconnect power
and release all pres-

sure from the system before attempting
to install, service, relocate or perform any
maintenance.

Operation

PRIMING THE SHALLOW WELL PUMP

To prevent damage
to the pump, do not

start motor until pump has been filled
with water.

1. Remove prime plug (Figure 4 or 5).

2. Fill pump and piping completely full

of water.

3. Replace the prime plug.

4. Open a faucet to vent the system.

5. Start the motor. Water will pump in

a few minutes. If pump fails to
prime in 5 minutes, stop motor and
refill pump with water. Priming
time is proportional to the amount
of air in inlet pipe.

6. Let the system operate for several

minutes to flush all pipes.

7. Close faucet and allow pump to

build pressure in tank. When the
pressure reaches the cut-out setting,
the motor will stop.

The system is now in operation and will
automatically cycle on demand.

Maintenance

Disconnect power
and release all pres-

sure from the system before attempting
to install, service, relocate or perform any
maintenance. Lock the power disconnect
in the open position. Tag the power dis-
connect to prevent unexpected applica-
tion of power.

Protect the pump
from freezing dur-

ing winter conditions.

DRAINING THE PUMP

Drain openings are provided on all
models. To drain the pump:

1. Remove drain plug and prime plug

to vent the system.

2. Drain all piping to a point below

the freeze line.

DRAINING THE TANK

Conventional tanks can be drained by
opening an outlet at the lowest point
in the system. Remove plug or the air
volume control to vent the tank.

Precharged tanks force virtually all the
water from the tank when system pres-
sure is released. No draining is neces-
sary.

RESTARTING PUMP

If the pump has been serviced, drained
or has not been used for some time, be
sure there is water in the pump hous-
ing (volute) and the piping to the well.
There must be water in the pump hous-
ing (volute) at all times when the pump
is running to avoid internal damage of
seal members (Priming the Shallow
Well).

WATERLOGGED TANKS:
CONVENTIONAL

When a tank system has an inadequate
ratio of air and water, the pump will
start and stop often and eradically.

1. Disconnect the power to the pump.

2. Open the lowest faucet in the sys-

tem to release all pressurized water
in the system.

3. Prime the pump (Priming the

Shallow Well).

4. Reconnect the power to the pump.

NOTE: As the pump refills the tank with
water, the air volume control supplies
the tank with the correct air to water
ratio for the system to operate. If the air
volume control is good, the pump will

Operating Instructions and Parts Manual

SBS50, SBS75, and SBS100

shut off at the desired cut-off and will be
adjusted correctly.

WATERLOGGED TANKS:
PRECHARGED
If a precharged tank becomes water-
logged, the bladder is normally leaking
or broken.

1. Test the tank by depressing the air

valve. The air valve will expel water if
the bladder is broken.

2. Replace the tank.

NOTE: Once a bladder is leaking or bro-
ken, the bladder cannot be repaired. The
tank must be replaced.

LUBRICATION

The bearings used in the pumps are life-
time lubricated at the factory and require
no additional lubrication.

PRECHARGED TANK

Some air is lost through the bladder in
any tank. To prevent tank failure, check
the tank precharge on a yearly basis.

1. Open a faucet nearest the tank and

allow all water to drain from the
tank.

2. Measure the tank precharge at the

valve stem using a tire gauge.

3. If necessary, adjust the precharge

with an air pump 28 - 30 psi on 1/2,
3/4 and 1 HP pumps.

REMOVING OLD SHAFT SEAL

Turn disconnect
switch to “off” posi-

tion.

1. Open a faucet nearest the tank and

allow all water to drain from the
tank.

Distance In Feet

From Meter To Motor

Dual

0

51

101

201

Element

To

To

To

To

Fuse

50

100

200

300

HP

Volt

250V

Wire Size

115

15

14

14

12

10

230

10

14

14

14

14

115

15

14

14

10

8

230

10

14

14

14

14

115

20

12

12

10

8

230

10

14

14

14

14

CHART 3 - RECOMMENDED FUSE & WIRING DATA - 60 HZ MOTORS

1/2

3/4

1