DEVICE SAFEGUARDS

AirChip 3000 Functions

Description

► Device write protection

Used to protect the HF6 with a password to prevent
unauthorized digital access by a digital user. Can be configured,
enabled or disabled

► Internal menu access from keypad

Used to prevent accidental changes to the HF6 settings and
temperature-humidity adjustment by disabling the MENU key on
the optional keypad. Can be enabled or disabled

PROCESS PROTECTION / PROTECTION OF OTHER DEVICES

AirChip 3000 Functions

Description

► Limit humidity output to 100 %RH

Used to prevent the humidity signal from exceeding
100 %RH when condensation forms on the sensor. Can be
enabled or disabled

► Out-of-limit value alarm

Used to specify the normal range for humidity, temperature and
the calculated parameter depending on the user application.
Can be configured, enabled or disabled

Out-of-limit values trigger a digital alarm which can be also be
seen on the optional display

► Bad sensor alarm

Built-in function. Cannot be disabled

A bad humidity or temperature sensor triggers a digital alarm
which can be also be seen on the optional display

► Fail safe mode

Used to specify a "safe" fixed value for humidity and for
temperature in the event of a sensor failure. Can be configured,
enabled or disabled

4.2 Factory default settings


Notes:

o

Configuration of the HF6 by the user and access to its functions requires a PC with the ROTRONIC HW4

software (version 2.1.1 or higher) installed. Service cable AC3006 or AC3009 is used to connect the HF6
service connector to a USB port of the PC. The HF65 can also be connected to the PC using either its
USB, Ethernet or RS-485 interface


o

Settings and functions that can also be either partially or fully accessed from the optional keypad are

marked with the letter K (see also Operation > Internal Menu).


Configurable Settings

Applicability

Factory default

Unit system (Metric or English)

K HF63, HF65

As per ordering code

Analog signal type (4…20 mA or other)

HF63

As per ordering code

Psychrometric calculation

HF63, HF65

As per ordering code

Output 1 parameter, scale and unit

HF63

As per ordering code (%RH or DP)

Output 2 parameter, scale and unit

HF63

Temperature, unit as per ordering code

Display resolution (optional)

HF63, HF65

1 decimal

Display backlight (optional)

K HF63, HF65

Always on

Displayed parameters

K HF63, HF65

As per ordering code