4.14.3-2 Primary/secondary control operation amount increase time

Setting items:

Primary/secondary control operation amount increase time: 0 to 3600 [second] (no function by setting at 0
[second])

Operation description:

For a remote run, apply a limit on the operation amount such that the ratio of the operation amount to the
calculated operation amount is from 0% at the start to 100% at the setting time.
The setting is effective also during AT.
If the setting is changed, control results change; redo the AT.
Operation is performed only at the control start (RDY to RUN or MAN or AT)
Care must be used, as no limit applies by the operation amount increase time after the setting time.

100%

Operation amount

Time

0

oHtM

Calculated operation amount

Limited operation amount

0%

oHtM

RDY

RUN

* No compensation applies
after the setting time.

Calculated operation
amount

Limited operation
amount

100%

100%

0%

0%

Time

4.15

Key lock

When a change of each parameter is attempted in a lock after lock ON/OFF is elected, “LOC” is displayed in the
SV display section.

RUN

OUT

EV1

EV2

EV3

EV4

TS1

TS2

TS3

TS4

AUTO

MANU

AT

END

TIME

PTN

STP