List of models, Standard specifications 8.1 general specifications, 2 standard and performance – TOHO ELECTRONICS TTM-339 User Manual

Page 29

Advertising
background image

- 29 -

7. List of models

TTM-339-□ □-□□□□□□

① ② ③

Symbol

Item

Description

Size

96 x 96

Input

Multi-input: Thermocouple, resistance temperature detector, voltage and current

OUT1 (Primary

control)

R

Relay contact output

P

SSR drive voltage output (0 to 12 VDC)

I

Current 4 to 20 mADC output

OUT2

(Primary/secondary

control)

N

None

R

Relay contact output

P

SSR drive voltage output (0 to 12 VDC)

I

Current 4 to 20 mADC output

Option

A

Relay contact outputs EV1 to EV3 *1

B

Relay contact output END signal output

C

Open collector outputs TS1 to 4, TIME, EV4 output *2

D

CT input *3

E

No-voltage contact input

M Communications RS-485

T English version panel sheet

*1

No EV3 if a relay contact output is selected for OUT1. No EV2 if a relay contact output is selected for OUT2.

*2

No EV4 if a relay contact output is selected for OUT1 or OUT2.

*3

Select I for OUT1 or OUT2. This CT is of a type to limit the operation amount but not to detect disconnection. It is

effective for the PID control of the heat control.

8. STANDARD SPECIFICATIONS

8.1 General specifications

Memory element

EEPROM

Input/Output isolation

Between Output area(control, event output) and Input area (process, CPU) and Power source

Power voltage

100 - 240 VAC, 50/60 Hz (Allowable voltage range: 85 - 110 %)

Power consumption TTM-339

10VA(AC264V)

Momentary power cut off

Within 1 cycle(20mS), Cut 100% power off on 100V AC at max. power consumption

Isolation resistance

Measurement terminal - case 500 VDC, 20 M

.

Power terminal - case 500 VDC, 20 M

.

Withstand voltage

Measurement terminal - case 1500 VAC for a minute.
Power terminal - case 500 VAC for a minute.

Operation
environment

Temperature 0~50℃

Humidity

20 - 90 %RH (no dew condensation allowed)

Set angle

Datum surface ±10 degrees

Vibration

0~0.2G

Transportation/sto
rage condition

Temperature -20 - +70 °C (no freeze or dew condensation allowed)
Humidity

5 - 95 %RH (no dew condensation allowed)

8.2 Standard and performance

PV input area





Input type



Thermocouple K,J,T,E,R,S,B,N,U,L,WRe5-26,PR40-20,PLⅡswitchable.

Effect of outer resistance approx.0.5μV/Ω
Indicating over, when wire is disconnected

R.T.D.

Pt100, JPt100 switchable
Allowable lead wire resistance 10Ωor less(per wire)
Indicating over, when wire is disconnected(for all of A, B and b)

Sampling time 0.2 sec. (same as output change frequency)
PV correct.

-199.9~999.9℃(

) or -199~999℃(

)

Display/
Setting


Display type



PV/character

5-digit 7 segment LCD(back light colors of red, green and orange) letter height
20mm

Set value

5-digit 7 segment LCD(back light colors of red) letter height 8mm

Status

1-digit 6 segment LCD(back light colors of red)

Pattern display

2-digit 7 segment LCD(back light colors of green)

Step display

2-digit 7 segment LCD(back light colors of green)

Advertising