TOHO ELECTRONICS TTM-339 User Manual

Page 28

Advertising
background image

- 28 -

5.12

List of the alarm temperature setting mode setting

Name

Setting content

Initial value

1

E1H Event 1 upper limit setting

See Section 6.6 “Common parameter setting mode SET 5 to 8.”

2

E1L Event 1 lower limit setting

3

E2H Event 2 upper limit setting

4

E2L Event 2 lower limit setting

5

E3H Event 3 upper limit setting

6

E3L Event 3 lower limit setting

7

E4H Event 4 upper limit setting

8

E4L Event 4 lower limit setting

5.13

List of the PID setting mode setting

Name

Setting content

Initial value

1

P1 Proportional band setting for PID No. 1 (low temperature)

See Section 6.5 “Common parameter setting mode SET 4.”

2

I1 Integral time setting for PID No. 1 (low temperature)

3

D1 Derivative time setting for PID No. 1 (low temperature)

4

PM1 Intermediate point 1 setting for the PID range

5

P2 Proportional band setting for PID No. 2 (intermediate

temperature)

6

I2 Integral time setting for PID No. 2 (intermediate temperature)

7

D2 Derivative time setting for PID No. 2 (intermediate temperature)

8

PM2 Intermediate point 2 setting for the PID range

9

P3 Proportional band setting for PID No. 3 (high temperature)

10

I3 Integral time setting for PID No. 3 (high temperature)

11

D3 Derivative time setting for PID No. 3 (high temperature)

5.14

Caution

Care must be used for the names with suffixes as described below:
*1: Setting related to steps in a run cannot be changed.
*2: No change is possible during a run.
*3: SAVE (all settings writing) is performed.


6. Measurement range and indicator resolution

Input type

Standards

Measurement/measurement range

Indicator resolution

Thermocouple

K

JIS C 1602-1995

-200.0 to +1372.0

1

C / 0.1

C

J

JIS C 1602-1995

-200.0 to +1200.0

1

C / 0.1

C

T

JIS C 1602-1995

-200.0 to +400.0

1

C / 0.1

C

E

JIS C 1602-1995

-200.0 to +1000.0

1

C / 0.1

C

R

JIS C 1602-1995

-50 to +1768

1

C

S

JIS C 1602-1995

-50 to +1768

1

C

B

JIS C 1602-1995

0 to 1800

1

C

N

JIS C 1602-1995

-200.0 to +1300.0

1

C / 0.1

C

U

DIN

-200.0 to +400.0

1

C / 0.1

C

L

DIN

-200.0 to +900.0

1

C / 0.1

C

WRe5-26

ASTM

0 to 2300

1

C

PR40-20

ASTM

0 to 1880

1

C

PLII

ASTM

0.0 to 1390.0

1

C / 0.1

C

Resistance temperature

detector

Pt100

JIS C 1604-1997

-200.0 to +850.0

1

C / 0.1

C

J Pt100

JIS C 1604-1997

-200.0 to +510.0

1

C / 0.1

C

Voltage

0 - 1 VDC

-19999 to +29999

Display range of 20000

or less

Random change of

decimal point position

allowed

0 - 5 VDC

1 - 5 VDC

0 - 10 VDC

0 - 10 mVDC

Current

4 - 20 mADC