NOx referenced to NO

2

NOx in mg/m

3

= NO in ppm multiplied by 2.05 multiplied by (1 + assumed

NO

2

percentage)


or

NOx in mg/m

3

= NO in mg/m

3

divided by 1.34, multiplied by 2.05 and

multiplied by (1 + assumed NO

2

percentage)


normalising readings

normalised reading = initial reading multiplied by (21 minus the O

2norm

setting) and then divided by (21 minus the actual O

2

reading)

BOTH NO and NO2 sensors Fitted


Working in ppm

NOx = NO + NO

2

normalising readings

ppmn = initial reading in ppm multiplied by (21 minus the O

2norm

setting) and then

divided by (21 minus the actual O

2

reading)


Working in mg/m

3


The user can select how the readings are referenced.

NOx = SUM
NOx = NO
NOx = NO

2

NOx = SUM

NOx in mg/m

3

= NO in ppm multiplied by 1.34 plus NO

2

in ppm multiplied by 2.05


NOx = NO


NOx in mg/m

3

= (NO in ppm plus NO

2

in ppm) multiplied by 1.34


NOx = NO

2


NOx in mg/m3 = (NO in ppm plus NO

2

in ppm) multiplied by 2.05

normalising readings

ppmn = initial reading in ppm multiplied by (21 minus the O

2norm

setting) and then

divided by (21 minus the actual O

2

reading)


mg/m

3

n = initial reading in mg/m

3

multiplied by (21 minus the O

2norm

setting) and

then divided by (21 minus the actual O

2

reading)

Advertising