KM9106 Operators Manual

63

ONLY an NO

2

sensor fitted


When there is only an NO

2

sensor fitted the NOx function is disabled

NO

2

in mg/m

3

= NO

2

in ppm multiplied by 2.05

normalising readings

ppmn = initial reading in ppm multiplied by (21 minus the O

2norm

setting) and then

divided by (21 minus the actual O

2

reading)


mg/m

3

n = initial reading in mg/m

3

multiplied by (21 minus the O

2norm

setting) and

then divided by (21 minus the actual O

2

reading)