Blue platen switch is dirty, Cannot adjust paper feed, Check printed document – Canon imagePROGRAF iPF6450 User Manual

Page 146: Spectrophotometer unit not connected, Spectrophotometer sensor not mounted

Advertising
background image

Cause

Corrective Action

(See "Paper that can be used in Color Calibration.")

→User's Guide

(See "Color Checks Using the Spectrophotometer Unit (option).")

→User's Guide

Set Set Exec. Guide to Off on
the Control Panel menu.
(See "Menu Structure.")

→P.66

Before borderless printing, move the blue platen switch.

Before borderless printing, move the blue platen switch.

Cause

Corrective Action

The blue Switch on the platen was set to the side opposite ●
when a borderless print job was received.

Before borderless printing, set the blue Switch on the platen to the ● side.
(See "Setting the Blue Switch on the Platen.")

→P.118

Blue platen switch is dirty.

Blue platen switch is dirty.

Cause

Corrective Action

The blue Switch on the platen is dirty.

Open the Top Cover and clean the blue Switch on the platen.
(See "Cleaning Inside the Top Cover.")

→P.51

Move the blue platen switch No.xx to the right. (xx represents a number)

Move the blue platen switch No.xx to the right. (xx represents a number)

Cause

Corrective Action

The printer has detected that the blue Switch on the platen needed in
maintenance during printing is set away from the ● mark.

Set blue platen Switch of the indicated number toward the ● side.
(See "Setting the Blue Switch on the Platen.")

→P.118

Cannot adjust paper feed.

Cannot adjust paper feed.

Cause

Corrective Action

The Printhead nozzles are clogged.

Execute Adj. Quality again, as follows.

1.

Press the OK button to clear the error.

2.

Print a test pattern to check the nozzles.
(See "Checking for Nozzle Clogging.")

→User's Guide

3.

Clean the Printhead if the nozzles are clogged.
(See "Cleaning the Printhead.")

→P.53

4.

Execute Adj. Quality again.
(See "Automatic Banding Adjustment.")

→P.100

Highly transparent film is loaded that cannot be used
for automatic feed amount adjustment.

Press the OK button to clear the error, and then adjust the feed amount manually.
(See "Manual Banding Adjustment.")

→User's Guide

Check printed document.

Check printed document.

Cause

Corrective Action

The Printhead nozzles are becoming clogged.

If printing is faint, clean the Printhead.
(See "Cleaning the Printhead.")

→P.53

Spectrophotometer Unit not connected.

Spectrophotometer Unit not connected.

Cause

Corrective Action

The Spectrophotometer Unit is not installed correctly.

Turn off the power and reinstall the Spectrophotometer Unit.

Spectrophotometer Sensor not mounted.

Spectrophotometer Sensor not mounted.

Cause

Corrective Action

The Spectrophotometer Sensor to be loaded
into the Spectrophotometer Carriage is not in-
stalled correctly.

Turn off the power, and reinstall by pushing the two connectors all the way into the Spec-
trophotometer Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→User's Guide

Before borderless printing, move the blue platen switch.