Spectrophotometer Unit Calibration white tile error.

Spectrophotometer Unit Calibration white tile error.

Cause

Corrective Action

The White Calibration Tile is
not installed.

Install the White Calibration Tile.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→User's Guide

The White Calibration Tile is
dirty.

Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.54

The performance of part of the
Spectrophotometer Sensor
may be impaired.

If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the
Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→User's Guide

Spectrophotometer Unit eject guide not mounted.

Spectrophotometer Unit eject guide not mounted.

Cause

Corrective Action

The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.

Make sure that the Spectrophotometer Eject Guide is loaded in the correct
position, push it in all the way, and press the OK button.

There is a foreign object on the Spectrophotometer Eject
Guide.

Remove the foreign object and press the OK button.

The performance of part of the Spectrophotometer Unit may
be impaired.

Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your Canon dealer for as-
sistance.

Spectrophotometer Unit Backing plate error.

Spectrophotometer Unit Backing plate error.

Cause

Corrective Action

The White/Black Backing Plate is not instal-
led correctly.

Remove and correctly attach the White/Black Backing Plate, and then press the OK button.
(See "Switching the White/Black Backing Plate (Optional) Color.")

→User's Guide

The White/Black Backing Plate is soiled.

Clean the White/Black Backing Plate and then press the OK button.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.54

Spectrophotometer up-down unit cover open.

Spectrophotometer up-down unit cover open.

Cause

Corrective Action

The Up-down Unit Cover of the Spectrophotometer Unit is open.

Close the Up-down Unit Cover and press the OK button.

Spectrophotometer Unit cover open.

Spectrophotometer Unit cover open.

Cause

Corrective Action

The Spectrophotometer Unit Cover of the Spectrophotometer Unit is
open.

Close the Spectrophotometer Unit Cover and press the OK button.

Spectrophotometer read error.

Spectrophotometer read error.

Cause

Corrective Action

The Spectrophotometer Sensor
to be loaded into the Spectro-
photometer Carriage is not in-
stalled correctly.

Turn off the power, and reinstall by pushing the two connectors all the way into the Spectrophotometer
Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→User's Guide

The color measurement pattern
was not printed correctly.

Check the color measurement pattern. If the printing is faint, clean the printhead and perform the opera-
tion again.
(See "Cleaning the Printhead.")

→P.53

The color measurement pattern
is out of alignment.

Pulling or lifting a printed color measurement pattern may cause the pattern to come out of alignment.
Perform the operation again taking care not to touch the color measurement pattern.

Execute Feed Priority to improve the printing position of the pattern for color measurement.

iPF6450

Spectrophotometer Unit Calibration white tile error.

Basic Guide

Error Message

Messages regarding printing or adjustment

147

Advertising