Canon imagePROGRAF iPF6450 User Manual

Page 59

Advertising
background image

Important

When handling the White/Black Backing Plate, do
not touch the white backing plate (a) or black back-
ing plate (b) directly with your hands.
If the surface becomes dirty or scratched, the print-
er may not be able to obtain the correct color
measurement results.

Make sure that no dirt remains in the grooves on
both ends of the Spectrophotometer Eject Guide.
If any dirt remains, the printer may not be able to
obtain the correct color measurement results.

Cleaning the Paper presser

Dirt on the surface of the Paper presser may be transferred onto the paper or the White/Black Backing Plate.

1

Turn the printer off.
(See "Turning the Printer On and Off.")

→User's Guide

2

Unplug the power cord from the outlet.

Caution

Always turn off the printer and unplug the power cord before cleaning or maintenance. Accidentally leaving the
printer on poses a risk of injury if you touch moving parts inside the printer.

3

If the Up-down Unit is lowered, open the Spectro-
photometer Unit Cover and lift up the central part
(near the blue label) of the Up-down Unit.

Important

Lifting up the ends of the Up-down Unit may cause damage.

iPF6450

Cleaning the Spectrophotometer Unit (option) Parts

Basic Guide

Consumables and Maintenance

Cleaning the Printer

59

Advertising