Cause

Corrective Action

The color measurement pattern
is out of alignment.

(See "Automatic Banding Adjustment.")

→P.100

If the same message is displayed again after performing the above operation, set Pattern Size to Large
on the Control Panel menu and perform the operation again.
(See "Menu Structure.")

→P.66

Alternately, it may be resolved by selecting Air Drying in Drying Method in the Color Measurement
Preferences
dialog box in the Color Calibration Management Console and selecting the Dry Separated
Chart
check box if it is off.
(See "Acquiring Color Measurement Data For Any Color Chart.")

→User's Guide

(See "Acquiring Color Measurement Data For Any Color Chart.")

→User's Guide

The performance of part of the
Spectrophotometer Unit may be
impaired.

Turn off the printer and wait a while before restoring power, and then perform the operation again.
If the same message is displayed again, contact your Canon dealer for assistance.

Clean calibration white tile because it may be dirty.

Clean calibration white tile because it may be dirty.

Cause

Corrective Action

The White Cal-
ibration Tile
may be dirty.

Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")

→P.54

If this message is still displayed after cleaning the White Calibration Tile, we recommend adjusting the Spectrophotome-
ter Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit (option).")

→User's Guide

Clean calibration white tile because it may be dirty.