Programming mode continued, Manual regeneration options – Water Inc wi-hp9100-TS Upflou User Manual

Page 10

Advertising
background image

Level IV Viewing History - H Values
Historical information can be viewed by pressing the SET and

DOWN buttons simultaneously, with the 9100 TS control in the

home position. Release both buttons when the control displays

an “H” value. Press the UP or DOWN buttons to navigate to

each setting.

PROGRAMMING MODE continued

H#

Description

Range

Notes

H0*

Initial Setting Value

Cubic Feet or Liters

Resin Volume, Holding SET for 3 seconds

will reset control to factory defaults

H1

Days since last regeneration

0-255

H2

Current Flow Rate

Depends on turbine used

H3

Water used today in gallons or m

3

since Time of

Regeneration

0-131,070 or 0-1,310.7 m

3

H4

Water used since last regeneration in gallons or m

3

0-131,070 or 0-1,310.7 m

3

H5*

Total water used since reset in 100s

0-999900 gallons or 0-9999m

3

Holding SET key for 3 seconds will reset

H5 and H6 to zero.

H6*

Total water used since reset in 1,000,000

4,294 x 10

6

gal or 4,264 x 10

4

m

3

Holding SET key for 3 seconds will reset

H5 and H6 to zero.

H7

Average usage for Sunday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H8

Average usage for Monday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H9

Average usage for Tuesday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H10

Average usage for Wednesday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H11

Average usage for Thursday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H12

Average usage for Friday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H13

Average usage for Saturday in gallons or m

3

0-131,070 gallons or 0-1,310.70 m

3

H14

Average service cycle

0-255 days

Last 4 Regens

H15*

Peak Flow Rate

0-200 gpm or 1000Lpm

Holding SET key for 3 seconds will reset

H15 to zero.

H16

Day and Time of Peak Flow Rate

Time and day that peak flow occurred

H17*

Months since service

0-2184 months

Holding SET key for 3 seconds will reset

H17, H18 and H19 to zero.

H18

Number of Low Salt Alarms

0-65536

H19

Number of Reduced Capacity Alarms

0-65536

H r

Number of regenerations since last serviced

0-65536

Holding Set key for 3 seconds will reset Hr to zero.

*H0, H5, H6, H15, H17 values can be reset by pressing and holding for 3 seconds while the value is being displayed.
Program Reset
The 9100 TS control can be reset to original factory

parameters when viewing the H0 parameter. Press and hold

the SET button for three seconds while H0 is displayed.

Release the button. All settings except for Time of Day and Day

of Week will be reset. The 9100 TS control will now display the

resin volume. Refer to Level I Programming.
NOTE: After a program reset all programmed values will

reset to default settings.

Manual Regeneration Options

The 9100 TS control features several options that offer

additional flexibility for manually regenerating the softener. On

twin tank systems the tank in standby will move to service.

Then the tank that was in service will be regenerated..

Delayed Manual Regeneration
Press and release the REGEN button to start a delayed

manual regeneration. The Regeneration icon on the display

will flash indicating a regeneration will start when the time of

day reaches the programmed time of regeneration. Pressing

the REGEN button again will turn off the regeneration icon and

cancel the delayed regeneration.

Immediate Manual Regeneration
Pressing and holding the REGEN button for three seconds

starts an immediate manual regeneration. A solid regeneration

icon will be displayed. The control will immediately begin a

regeneration on the tank in service.

Delayed Second Regeneration
Pressing and releasing the REGEN button while the control is

in regeneration will program the control for a delayed second

regeneration. A flashing x2 icon next to the regeneration icon

will appear indicating a second regeneration will start when

the time of day reaches the programmed time of regeneration.

The delayed second regeneration will be performed on the new

tank in service.

Double Immediate Manual Regeneration
Back-to-Back manual regenerations are initiated by pressing

and holding the REGEN button for three seconds while the

control is in the regenerating mode. A solid x2 icon next to

the regeneration icon will appear indicating a second manual

regeneration will start immediately after current regeneration is

complete.

10 • JA11 9100 TS Upflow