9100 TS Controller

Problem

Cause

Solution

ERR 1 is displayed.

Program settings have been corrupted.

Press any key and reprogram Level I settings.

ERR 3 is displayed.

Controller on tank 1 does not know the

position of the camshaft. Camshaft should

be rotating to find Home position.

Wait for two minutes for the controller to return to Home

position. The hourglass should be flashing on the

display indicating the motor is running.

Camshaft on tank 1 is not turning during

ERR 3 display.

Check that motor is connected. Verify that motor wire

harness is connected to motor and controller module.
Verify that Home switch sensor is connected and in

place.
Verify that motor gear has engaged cam gear.
If everything is connected, try replacing in this order:
1. Wire Harness, Motor, Home Switch, Sensor Assy
2. Controller

Camshaft on tank 1 is turning more than five

minutes to find Home position.

Verify that Home Switch sensor is in place and

connected to wire.
Verify that camshaft is connected appropriately.
Verify that no dirt or rubbish is clogging any of the cam

slots.
If motor continues to rotate indefinitely, replace the

following components in this order:
1. Wire Harness, Motor, Home Switch, Sensor Assy
2. Controller

Regeneration starts but control shows Err3

before completing regeneration.

Check that motor is connected. Verify that motor wire

harness is connected to motor and controller module.
Verify that Home Switch sensor is connected and in

place.
Verify that motor gear has engaged cam gear.
If everything is connected, try replacing in this order:
1. Wire Harness, Motor, Home Switch, Sensor Assy
2. Controller

ERR 4 is displayed.

Hardness front detected with no water flow.

ERR 6 is displayed.

Conductivity sensors' reading out of range.

Defective sensors or no sensors are

connected

Check which tank in service and check if the sensors

have been connected properly. If already connected,

replace conductivity sensor probes with new ones.

Check Salt Light is displayed - Press

the regen button to turn off the check

salt light.

No regenerant draw or insufficient

regenerant detected during regeneration.

Ensure salt/regenerant is available.
Check for regenerant draw.
Inspect regeneration line for leaks.