PROGRAMMING MODE continued

Level III Cycle Programming - C Values
Several Level III program parameters can be adjusted to

fine-tune valve operation for non-standard applications.

Typically these parameters will not need to be adjusted as

the default settings accommodate most applications. Contact

your Water Treatment Professional before attempting any

programming. The parameters are accessible by pressing and

holding the UP and SET buttons until the display shows a “C”

value.
NOTE: The control must be in the treated water position to

change settings.

C#

Description

Range

Minimum

Increments

Default Setting

Notes

C1*

Brine Draw

0-200

1 Min

See Notes

Automatically calculated from resin volume

and salt dosage settings and draw rate.

C2

Slow Rinse

0-200

See Notes

Initial time automatically calculated to provide

two bed volumes of rinse.

C3

Standard Backwash

0-20

7

Flow rate dictated by size of drain line flow

controller.

C4

Standard Fast Rinse

0-200

3

Rinses residual regenerant from tank.

C5*

Refill

0-200

See Notes

Automatically calculated from resin volume

and salt dosage settings and refill rate.

C13

Cleaning Backwash

0-200

14

Control uses C13 in place of C3 when the

number of standard regenerations is more than

or equal to the cleaning cycle interval P19.

C14

Cleaning Fast Rinse

0-200

6

Control uses C14 in place of C4 when the

number of standard regenerations is more than

or equal to the cleaning cycle interval P19.

*Cannot be changed in Level III Cycle Programming.

9100 TS Upflow JA11 • 9