Troubleshooting – Water Inc wi-hp9100-TS Upflou User Manual

Page 25

Advertising
background image

Problem

Cause

Correction

1. Water conditioner fails to regenerate.

A. Electrical service to unit has been

interrupted

A. Assure permanent electrical service (check fuse,

plug, pull chain, or switch)

B. Timer is defective.

B. Replace timer.

C. Power failure.

C. Reset time of day.

2. Hard water.

A. By-pass valve is open.

A. Close by-pass valve.

B. No salt is in brine tank.

B. Add salt to brine tank and maintain salt level above

water level.

C. Injector screen plugged.

C. Clean injector screen.

D. Insufficient water flowing into brine tank.

D. Check brine tank fill time and clean brine line flow

control if plugged.

E. Hot water tank hardness.

E. Repeated flushings of the hot water tank is

required.

F. Leak at distributor tube.

F. Make sure distributor tube is not cracked. Check

O-ring and tube pilot.

G. Internal valve leak.

G. Replace seals and spacers and/or piston.

H. Meter is not measuring flow.

H. Check meter with meter checker.

3. Unit used too much salt.

A. Improper salt setting.

A. Check salt usage and salt setting.

B. Excessive water in brine tank.

B. See problem 7.

4. Loss of water pressure.

A. Iron buildup in line to water conditioner.

A. Clean line to water conditioner.

B. Iron buildup in water conditioner.

B. Clean control and add mineral cleaner to mineral

bed. Increase frequency of regeneration.

C. Inlet of control plugged due to foreign

material broken loose from pipes by recent

work done on plumbing system.

C. Remove piston and clean control.

5. Loss of mineral through drain line.

A. Air in water system.

A. Assure that well system has proper air eliminator

control. Check for dry well condition.

B. Improperly sized drain line flow control.

B. Check for proper drain rate.

6. Iron in conditioned water.

A. Fouled mineral bed.

A. Check backwash, brine draw, and brine tank

fill. Increase frequency of regeneration. Increase

backwash time.

7. Excessive water in brine tank.

A. Plugged drain line flow control.

A. Clean flow control.

B. Plugged injector system.

B. Clean injector and screen.

C. Timer not cycling.

C. Replace timer.

D. Foreign material in brine valve.

D. Replace brine valve seat and clean valve.

E. Foreign material in brine line flow control.

E. Clean brine line flow control.

8. Softener fails to draw brine.

A. Drain line flow control is plugged.

A. Clean drain line flow control.

B. Injector is plugged.

B. Clean injector

C. Injector screen plugged.

C. Clean screen.

D. Line pressure is too low.

D. Increase line pressure to 20 P.S.I.

E. Internal control leak

E. Change seals, spacers, and piston assembly.

F. Service adapter did not cycle.

F. Check drive motor and switches.

9. Control cycles continuously.

A. Misadjusted, broken, or shorted switch.

A. Determine if switch or timer is faulty and replace it,

or replace complete power head.

10. Drain flows continuously.

A. Valve is not programming correctly.

A. Check timer program and positioning of control.

Replace power head assembly if not positioning

properly.

B. Foreign material in control.

B. Remove power head assembly and inspect bore.

Remove foreign material and check control in various

regeneration positions.

C. Internal control leak.

C. Replace seals and piston assembly.

TROUBLESHOOTING