PROGRAMMING MODE continued

In Service Display

Time & Day

Regen Time & Day

Salt Amount

SU MO TU WE TH FR SA DAYS

Capacity

Time & Day

Regen Time & Day

Salt Amount

SU MO TU WE TH FR SA DAYS

Capacity

Hardness

Hardness

Figure 6

The display shows the number of the tank in service (small

digit next to CPH position). The display also alternates

between Capacity Remaining and Flow Rate (faucet icon) for

the tank in service.
NOTE: The Regen icon is only on when in regeneration.
NOTE: The faucet icon is displayed on all the 9100 TS

controls when there is flow. The 9100 TS will show

the faucet icon when the flow rate is displayed,

even if the flow rate is zero. The faucet icon will

turn off when the capacity is displayed. In service

flow rate display can be replaced with a clock

display using Level II Programming (Parameter

P10).

Programming Overview

The 9100 TS control includes multiple program levels that

allow water treatment professionals to customize the system

for many water conditions. Additionally, historical data can be

viewed allowing quick and easy troubleshooting. In most cases

Level I Programming is all that is required to set up the water

conditioning system for proper operation. A brief description of

each program level is listed below.
Level I - Used to program control for normal applications.
Level II (P-Values) - Allows the installer to customize

programming for non-standard applications.
Level III (C-Values) - Allows the installer to adjust length of

select cycles for non-standard applications.
Level IV History (H-Values) - Allows access to historical

information for troubleshooting the system.
NOTE: If a button is not pushed for thirty seconds, the

control returns to normal operation mode.

Level I Programming
The 9100 TS control can be quickly programmed by following

the sequential procedure in the section "Placing Water

Conditioning System Into Operation". Level I Program

parameters are those that can be accessed by pressing the

UP or DOWN buttons. Step-by-step instructions are shown on

previous page.

• Resin Volume Setting: Set to match the volume (cubic

feet) of resin in the mineral tank.

• Time of Day: Includes PM indicatior. Can be set to display

as a 24-hour clock. See Level II programming.

• Day of Week: Set to actual day of the week.
• Time of Regeneration: Fully adjustable. Default is 2:00 AM.
• Days Override: Range 0.5 to 30 days. Leave at 0 to disable.
• Salt Dosage: Set at pounds of salt per cubic foot of resin

in the conditioner tank.

NOTE: When the control is set up for a twelve-hour clock

a PM indicator will illuminate when the displayed

time is in the PM hours. There is no AM indicator.

Programming the Lockout Feature
All Level I parameters can be locked out when the control is in

Level II Programming. Simply press the REGEN button during

Level II Programming and a lock icon will appear indicating that

the specific setting has been locked out. When locked out, the

setting cannot be adjusted in Level I Programming. To disable

the Lock Out feature, press the REGEN button when in Level

II. The lock icon will not be displayed.

Resin Volume
The amount of resin can be determined by the diameter of the tank.

Tank Diameter

(inches)

Resin Volume

US

Metric

8

0.90

9

1.25

10

1.75

12

2.25

9100 TS Upflow JA11 • 7