Installation Instructions

15

M412060

Combined Exhaust Manifold

Figure 4

VERTICAL EXHAUST INSTALLATION

HORIZONTAL EXHAUST INSTALLATION

180°

Sweep Elbow

No Screen

or Cap

2 in (5.1 cm)

Minimum

Clearance

30 in (76.2 cm)

Minimum

Clearance

0 in

Clearance

Permitted

for First

4 in (10.2 cm)

12 in (30.5 cm)

Minimum

Clearance

0 in Clearance

Permitted

for First

4 in (10.2 cm)

2 in (5.1 cm)

Minimum

Clearance

No

Screen

or Cap

Wall

NOTE: Maximum length of
exhaust duct is 14 feet (4.3
meters) beyond manifold duct.

NOTE: Maximum length
of exhaust duct is
14 feet (4.3 meters)
beyond manifold duct.

Clearance permitted to combustible material
36 in (91.4 cm) recommended for maintenance purposes
24 in (61.0 cm) minimum

Wall

TMB2153N

12 in (30.5 cm)

Minimum

Clearance

Manifold

Duct

Manifold

Duct

0 in