Installation Instructions

23

M412060

1. Install a fused disconnect switch, or a circuit

breaker, as close to the tumbler as possible. If
more than one stacked tumbler is being installed,
provide a disconnect switch or circuit breaker for
each. This will make it possible to individually
disconnect stacked tumblers for maintenance
purposes.

2. Connect the conduit-encased leads to the

disconnect switch, or circuit breaker. Remove the
screw holding the upper junction box cover to the
upper junction box. Refer to Figure 10. Insert the
other end of conduit through the hole in the top
of the junction box. Connect the wire leads to the
appropriate terminals of the terminal block
(L1 and L2 or L1 and N). If the electrical service
is 120 Volt, connect the neutral wire to
NEUTRAL. The ground wire must be connected
to the green ground screw located in the junction
box. Refer to Figure 10.

3. Reinstall cover on the junction box.

Grounding Instructions

This drying tumbler must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electronic shock by providing a path of least
resistance for electric current. This dryer must be
connected to a grounded metal, permanent wiring
system or to the ground screw (located in the junction
box).

To reduce the risk of fire and electric
shock, check with a qualified
serviceperson for proper grounding
procedures. Improper connection of the
equipment grounding conductor may
result in a risk of electric shock.

W068R1

WARNING

Figure 10

TMB2161N

IEI

Board

Terminal

Block

Terminal

Jumper

Block

Ground

Screw