Installation Instructions

M412060

22

Electrical Requirements

Requirements

Provide adequate wiring and a 20 amp circuit breaker
for each stacked tumbler. The unit is designed to
accept ONE electrical hook-up through the top pocket
only. The tumbler is prewired to electrically operate
both the upper and lower units.

Refer to the chart below for requirements for specific
voltages.

IMPORTANT: If electrical supply is coming from a
three phase service, DO NOT connect a “Stinger
Leg” to a single phase machine.

NOTE: The electrical service to a gas tumbler must
be electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National Electric Code, ANSI/NFPA No. 70. The
gas service to a gas tumbler must conform with the
local codes and ordinances, or in the absence of
local codes and ordinances, with the latest edition
of the National Fuel Gas Code ANSI Z223.1.

The following steps outline the procedure for
connecting the electrical service to the tumbler. The
wiring diagram is attached to the rear of the tumbler.
Refer to Figure 10.

IMPORTANT: Do not connect the tumbler to any
voltage or current other than that specified on the
tumbler serial plate.

Heat Source

Electrical

Specs

Wires Required and

Terminal Block Connection

Gas

120/50 or 60/1

L1

N

Ground to Green Ground Screw

Gas

208/240/60/1

L1

N

L2

Ground to Green Ground Screw

Gas

220/60/1

L1

N

Ground to Green Ground Screw

Gas

240/50/1

L1

N

L2

Ground to Green Ground Screw

Gas Drying Tumblers

120 Volt

50/60 Hertz

1 Phase*

208/240 Volt

60 Hertz

1 Phase**

240 Volt

50 Hertz

1 Phase

220 Volt

60 Hertz

1 Phase

Wire Size

As Required by Local Codes

Disconnect Switch

20 Amp

Use Circuit

Breaker Only

15 Amp

2 Pole

Use Circuit

Breaker Only

15 Amp

2 Pole

Use Circuit

Breaker Only

15 Amp

2 Pole

Fusetron

20 Amp

Circuit Breaker

20 Amp

Number of Poles

1 2 2

2

*120 Volt, 60 Hertz, 1 Phase gas tumblers require a 120 Volt, 2-wire grounded system (Line 1, Neutral and Ground).

**208/240 Volt, 60 Hertz, 1 Phase gas tumblers require 3-wire grounded system (Line 1, Line 2, Neutral and separate ground).

All electrical connections should be made
by a qualified electrician.

To reduce the risk of electrical shock,
serious injury or death, before making any
electrical connections, de-energize the
electrical circuit being connected to the
tumbler. Never attempt to connect a live
circuit.

W650

WARNING