Installation Instructions

25

M412060

Instructions for Lighting and
Shutting Down Instant Electronic
Ignition System

1. Turn gas shut-off valve to “on” position (handle

parallel with gas line). Refer to Figure 12.

2. Start tumbler in drying cycle. Spark igniter will

begin sparking as the gas valve simultaneously
opens. The gas burner is ignited by the sparking
igniter. The igniter will then shut off. Burner will
remain on for as long as the temperature control
calls for heat.

3. Opening the loading door will extinguish burner

flames. Closing loading door and restarting
tumbler should cause gas to be re-ignited.

4. If gas does not light, open and close loading door

again and restart the ignition cycle.

IMPORTANT: The Instant Electronic Ignition
system will attempt to light the gas by sparking for
approximately 15 seconds. If gas does not ignite
within 15 seconds, the Instant Electronic Ignition
control will go into safety lockout (if this occurs, the
red light on the IEI board will be illuminated). The
valve will not open until the Instant Electronic
Ignition control is reset. Reset by opening and
closing the loading door.

If condition persists, check that the gas shut-off
valve is open and that gas service is properly
connected. If condition still persists, remove
tumbler from service.

5. To remove tumbler from service, disconnect

electrical service and turn gas shut-off valve to
“off” position (handle at right angle to gas line).
Refer to Figure 12.

Figure 12

Off

Position

On

Position

TMB2162N

Gas

Line

Advertising