Operating Checks

Electronic Control

The stacked tumbler comes equipped with an
Electronic Control. The Electronic Control gives the
owner a variety of programming options. To learn how
to use the Electronic Control in more detail, consult
the supplemental manual provided with this machine.

Preliminary Operating Check

1. Remove or open all panels, drawers and guards

and check accessible bolts, nuts, screws,
terminals and fittings for tightness (only remove
front panel of the belt guard).

2. Replace belt guard front panel on rear of

machine.

3. Set Electronic Control for Free Dry, refer to

Electronic Control Supplemental Manual for
instructions.

4. Start the tumbler by pressing and releasing the

START pad. Open the loading door. The cylinder
should stop rotating within seven seconds after
the door is opened a distance of 1-3/4 to 2-1/4
inches (45 to 57 mm). If it does not, adjust the
loading door interlock. Refer to the appropriate
paragraph in the Adjustments section of this
manual.

5. Start the tumbler and check the burner flame.

6. Load the cylinder with 30 pounds of cotton

clothes or clean rags.

7. Check the air flow switch operation by opening

the loading door. The heating system should shut
off when the loading door is opened a distance of
one to 1-1/2 inches (25 to 38 mm).

The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air, or an
obstruction in the exhaust duct. These should be
checked and the required corrective action taken
before attempting to adjust the airflow switch. To
adjust the airflow switch refer to appropriate
paragraph in the Adjustments section of this manual.

Guards/panels must be replaced prior to
energizing unit to reduce the risk of
possible serious injury.

W655

WARNING

The tumbler must not be operated if the
airflow switch does not shut off heating
system in step 8. Faulty airflow switch may
cause an explosive gas mixture to collect
in the tumbler.