Ampro Corporation COM 830 User Manual

Page 41

Advertising
background image

Chapter 3

Signals and Pinout Tables

COM 830

Reference Manual

35

SUS_S3#

Indicates system is in Suspend to RAM state.
Active low output. Also known as "PS_ON"
and can be used to control an ATX power
supply.

O 3.3VSB

PU 10k
3.3VSB

SUS_S4#

Indicates system is in Suspend to Disk state.
Active low output.

O 3.3VSB

PU 10k
3.3VSB

Not
supported

SUS_S5#

Indicates system is in Soft Off state.

O 3.3VSB

PU 10k
3.3VSB

WAKE0#

PCI Express wake up signal.

I 3.3VSB

PU 10k
3.3VSB

WAKE1#

General purpose wake up signal. May be used
to implement wake-up on PS/2 keyboard or
mouse activity.

I 3.3VSB

PU 10k
3.3VSB

BATLOW#

Battery low input. This signal may be driven
low by external circuitry to signal that the
system battery is low, or may be used to signal
some other external power-management event.

I 3.3VSB

PU 10k
3.3VSB

THRM#

Input from off-module temp sensor indicating
an over-temp situation.

I 3.3V

PU 10k
3.3V

THERMTRIP
#

Active low output indicating that the CPU has
entered thermal shutdown.

O 3.3V

PU 10k
3.3V

SMB_CK

System Management Bus bidirectional clock
line. Power sourced through 5V standby rail
and main power rails.

I/O
3.3VSB

PU 2k2
3.3VSB

SMB_DAT#

System Management Bus bidirectional data
line. Power sourced through 5V standby rail
and main power rails.

I/O
3.3VSB

PU 2k2
3.3VSB

SMB_ALERT
#

System Management Bus Alert – active low
input can be used to generate an SMI# (System
Management Interrupt) or to wake the system.
Power sourced through 5V standby rail and
main power rails.

I 3.3VSB

PU 10k
3.3VSB

Table 3-15. Power and GND Signal Descriptions

Signal

Description

I/O

PU/
PD

Comment

VCC_12V

Primary power input: +12V nominal. All
available VCC_12V pins on the connector(s)
shall be used.

P

VCC_5V_SBY

Standby power input: +5.0V nominal. If
VCC5_SBY is used, all available
VCC_5V_SBY pins on the connector(s) shall
be used. Only used for standby and suspend
functions. May be left unconnected if these
functions are not used in the system design.

P

Table 3-14. Power and System Management Signal Descriptions (Continued)

Advertising