Installation and Wiring

13

NXC-ME260 NetLinx Master-Ethernet Card/Module

Ethernet ports used by the ME260

SPE Port Connection/Wiring

Use an RJ-11 cable to connect the NXC-ME260 to an AXB-SPE Slave Port Expander.

The

EXPANSION OUT

port on the rear panel of the NXC-ME260 connects to the

EXPANSION IN

port on the rear panel of the AXB-SPE (FIG. 9).

You can daisy chain multiple AXB-SPE's by connecting the

EXPANSION OUT

on the primary

AXB-SPE to the

EXPANSION IN

port on the secondary, as shown in FIG. 10. The connecting RJ-11

cable should not exceed 6" in length. Repeat this process to connect up to nine AXB-SPE's.

Ethernet Ports Used by the ME260

Port type

Description

Standard Port #

ICSP

Peer-to-peer protocol used for both Master-to-Master and Master-to-device
communications.

For maximum flexibility, the Master can be configured to utilize a different
port than 1319, or disable ICSP over Ethernet completely from either
Telnet or the Program Port located on the rear of the Master itself.

1319 (UDP/TCP)

ICMP

When using version 1.XX of NetLinx Studio, you must be able to PING a
Master in order to be able to connect to it over a network.

Note: NetLinx Studio version 2.0 or higher allows a user the ability to

turn Off this requirement by de-selecting the "Automatically Ping the
Master Controller to ensure availability" feature from within the
TCP/IP Setting dialog (default condition is On).

ICMP

Telnet

The NetLinx telnet server provides a mechanism to configure and
diagnose a NetLinx system.

For maximum flexibility, the Master can be configured to utilize a different
port than 23, or disable Telnet completely from either Telnet or the Program
Port located on the rear of the Master itself. Once disabled, the only way to
enable Telnet again is from the Master’s Program port.

23 (TCP)

HTTP

The Master has a built-in web server that complies with the HTTP 1.0
specification and supports all of the required features of HTTP v1.1.

80 (TCP)

FTP

The NXC-ME260 has a built-in FTP server that conforms to RFC959.

21/20 (TCP)

Internet Inside The Internet Inside feature the Master uses, by default, is port 10500 for

the XML based communication protocol. This port is connected to by the
client web browser’s JVM when Internet Inside control pages are retrieved
from the on-board Master’s web server.

For maximum flexibility, the on-board Master can be configured to utilize a
different port than 10500 or to disable Internet Inside completely.

10500 (TCP)

FIG. 9 AXB-SPE (rear panel)

EXPANSION IN port (RJ-11)