AMX NetLinx Master-Ethernet Card/Module NXC-ME260 User Manual

Page 32

Advertising
background image

Communication and Firmware Update

26

NXC-ME260 NetLinx Master-Ethernet Card/Module

6.

Note the obtained IP Address.This information is later entered into the Master

Communication Settings dialog and used by NetLinx Studio 2.1 (or higher) to communicate

to the Master via an IP. This address is reserved by the DHCP server and then given to the

Master.

7.

Click the Set IP Information button to retain the IP Address on the Master. A popup window

then appears to notify you that Setting the IP information was successful and it is

recommended that the Master be rebooted.

8.

Click OK to accept the new changes.

9.

Click the Reboot Master button and select Yes to close the Network Address dialog. This

process closes the Network Addresses dialog and directs you to the Reboot the Master

Controller dialog.

10. Click Continue (from the Reboot Controller dialog) and wait for the System Master to reboot

and retain the newly obtained DHCP Address. The STATUS and OUTPUT LEDs should begin

to alternately blink during the incorporation. Wait until the STATUS LED is the only LED to

blink.

11. Use Ctrl+S to save your existing NetLinx Project with the new changes.

12. Right-click associated System number and select Refresh System. This establishes a new

connection to the specified System and populates the list with devices on that system.

FIG. 20 Network Addresses dialog (showing Get IP)

System Address

reflects the value

set in the Device

Addressing tab

Used to display the

IP Address

given to the Master

from the DHCP Server

DO NOT enter ANY IP information at this time, this step only gets the System Master
to recognize that it should begin using an obtained DHCP Address.

If the IP Address field is empty, give the Master a few minutes to negotiate a
DHCP Address with the DHCP Server, and try again. The DHCP Server can take
anywhere from a few seconds to a few minutes to provide the Master with an IP
Address.

If Studio can not establish communication with the Master, wait a few seconds and
click the Retry button.