Maintaining the Tape Drive

5158ACL Tape Drive Installation and User’s Guide 524955-002

5 -2

Running From the Front Panel

3. Remove any tape cartridge present in slot 1 (the slot nearest to the handle),

or in cleaning slot 1 (the first reserved slot in the magazine).

4.Insert the cleaning cartridge in the slot emptied in Step 3.

5.Insert the magazine in the tape drive.

6.Close the magazine door.

If you enable the Autoclean mode on the Configuration menu, the ACL runs the
cleaning cartridge automatically whenever the Use Cleaner LED comes on.

Running From the Front Panel

This procedure requires that the cleaning cartridge be installed in slot 1 of the
magazine and that no reserved slots are set.

1. At the Default screen, press Enter. The Main menu appears in

Figure 5-1

.

2. Scroll down to move the

cursor

next to Maintenance menu. Then press Enter

to select the Maintenance menu. The Maintenance menu appears in

Figure 5-2

.

Note. See “Required Location for the Cleaning Cartridge.”

Note. The cleaning cartridge is abrasive. Use it only when the Use Cleaner LED comes on.

Figure 5-1. Main Menu

Figure 5-2. Maintenance Menu