Application monitoring (beta), Application monitoring (beta) -11 – HP Storage Mirroring V4.5 Software User Manual

Page 33

Advertising
background image

3 - 11

Application Monitoring (BETA)

By default, application monitor settings are not available in this release of the Storage Mirroring

Application Manager. Application monitoring is only available when you launch Application Manager

using the command line

/exchange /advanced

option (

dtam /exchange /advanced

)

1.

If you select the Enable Application Monitoring checkbox, the remaining fields in Application

Monitor Settings area will be enabled.

2.

In the Monitor Interval field, enter the interval (in seconds) at which you want to check

application health.

3.

In the Error Threshold field, enter the number of consecutive errors that can be received

before an error alert appears.

4.

In the Type of Monitoring area, select one of the following options.

Built-in Monitoring Points—Use the default monitoring options.

Custom Script—Launch a batch file to check application health. Either type the name of the

script, or click Browse to locate a script.

5.

In the Username field, enter the fully-qualified user name that will be used to run WMI scripts.

The fully-qualified user name must be in the format domain\username or

username@domain.

6.

In the Password field, enter the password for the specified user account.

7.

Click the Test button to validate that the specified credentials are sufficient to run WMI scripts.

WARNING:

This feature is currently BETA and should not be used in production environments.

NOTE:

A message box will appear, asking you to confirm that you want to use this BETA

feature. To continue, click OK.
Application monitoring is not available when dealing with a cluster.

NOTE:

If you select Custom Script, you will also need to designate whether to use .PS1

(PowerShell) or .VB (VisualBasic) as the Script Engine. Make sure you select the

appropriate engine for your script type.
An example script that you can use as a basis for creating your custom script is

included in the \Samples subfolder where the Application Manager is installed.

NOTE:

The required credentials for running WMI scripts is full WMI access to the CIMV2

namespace. Under Windows 2008, the supplied credentials must also be allowed

through DCOM and User Access Control. It is recommended that a group be created

for running scripts, and that the required permissions be given to the group.
By default, the administrative group of a Windows 2008 machine has full WMI access.

However, DCOM and User Access Control settings may need to be adjusted.