Continuous Access XP volume pair status

Continuous Access XP displays pair status for each volume in the selected logical CU image (CUI) of the

connected XP1024/XP128.

Table 5

describes Continuous Access XP pair status descriptions. The MCU

maintains the status of the P-VOL and can change the pair status of the P-VOL and S-VOL. The RCU

maintains the status of the S-VOL and can change the pair status of the S-VOL but not the P-VOL. The MCU

detects when the RCU changes the S-VOL status (if path status is normal) and changes the P-VOL status

accordingly. You can display detailed pair status information using the Command View XP or XP Remote

Web Console GUI (Continuous Access XP Pairdisplay pane) or UNIX®/PC server host (RAID Manager

Pairdisplay command).
A volume not assigned to a Continuous Access XP pair has status SMPL. When a Continuous Access XP

pair is started, the MCU changes the status of the P-VOL and S-VOL to COPY. When the initial copy

operation is complete, the MCU changes the status of both volumes to PAIR. When you split a Continuous

Access XP pair (pairsplit-r), the MCU/RCU changes the status of the P-VOL and S-VOL to PSUS (if path

status is normal). When a pair is suspended due to an error condition, the MCU/RCU changes the P-VOL

and S-VOL status to PSUE (if path status is normal). When you delete a pair from the MCU (pairsplit-S), the

MCU changes the status of the P-VOL and S-VOL to SMPL (if path status is normal). When a pair is deleted

from the RCU, the RCU changes the S-VOL status to SMPL, and the MCU detects the pair deletion (if path

status is normal) and changes the P-VOL status to PSUS.
When a Continuous Access XP pair is split or suspended, the MCU generates a service information

message (SIM) to notify the hosts. This SIM results in a trap indicating the reason for suspension.

Continuous Access XP LUSE pair status

For Continuous Access XP LUSE pairs only, PDUB (dubious) status indicates the status of the Continuous

Access XP LUSE volume pair is COPY or PAIR, but the status of one or more individual LDEV pairs within

the Continuous Access XP LUSE pair is SMPL or PSUE (due to some error condition).

Continuous Access XP Asynchronous pair status

The Suspending and Deleting transitional states occur when a request to change Continuous Access XP

Async pair status is accepted, but the change to the requested status (PSUS, PSUE, or SMPL) is not yet

complete. These states are not reported to the host. For Suspending, you and the MCU can request the

status change. For Deleting, only you can request the status change. If you requested the status change,

the final status is reported at the end of the transition. If an error caused the status to change to PSUE, the

suspended status is reported at the beginning of the transition.

Table 5

Continuous Access XP Asynchronous pair status descriptions

Pair status

Description

P-VOL access

S-VOL access

SMPL

(simplex)

Volume is not currently assigned to a

Continuous

Access XP

volume pair. When this volume is

added to a

Continuous Access XP

pair, its status

changes to COPY.

Read/write

Read/write

COPY

Initial copy operation for this pair is in progress.

This pair is not yet synchronized. When initial

copy is complete, the status changes to PAIR.

Read/write

Read only

PAIR

Pair is synchronized. Updates to the P-VOL are

duplicated on the S-VOL.

Read/write

Read only