Continuous Access XP for the XP1024/XP128

When the Pairsplit-r pane closes, the list changes to the Pair Settings Parameter list (Pairsplit-r).

Figure 50

Pair Settings Parameter list (Pairsplit-r)

The Pair Settings Parameter list (Pairsplit-r) displays the following information for selected pairs:

Port, Group (TID), and LUN of the LU in the connected disk array.

S/N and SSID of the RCU (MCU if connected to the RCU).

S-VOL Wrt: Disable or enable. Enable means the S-VOL is available to receive read and write I/Os.

Kind: S-VOL or P-VOL Failure. Type of suspend operation.

Range: Split pairs in what measure: Group or LU (Async only).

Mode: Drain or purge pairsplit-r option (Async only).

Resuming Continuous Access XP volume pairs (Pairresync)

While a Continuous Access XP pair is split or suspended, the MCU does not perform update copy

operations to the S-VOL.

For a split/suspended Continuous Access XP Synchronous pair, the MCU may or may not continue

accepting write I/Os for the P-VOL, depending on the P-VOL fence level and pairsplit options (if

user-requested) (see

Creating Continuous Access XP volume pairs (Paircreate)

” on page 81 and

Splitting Continuous Access XP pairs (Pairsplit-r)

” on page 85).

For a split/suspended Continuous Access XP Async pair, the MCU and RCU tracks recordsets

discarded during pairsplit/suspension, and the MCU continues accepting write I/Os for the P-VOL.

The MCU tracks P-VOL cylinders updated while the pair is split/suspended.

If the RCU accepts write I/Os for a split S-VOL (S-VOL write enable), the RCU also tracks S-VOL cylinders

updated. When the split/suspended pair is resumed, the MCU merges the P-VOL and S-VOL cylinder

bitmaps to determine out-of-sync cylinders.
Use the Pairresync command to resume split/suspended Continuous Access XP pairs. When the

Pairresync command is selected, the Pairresync pane appears. Use the Pairresync pane to change pair

options, and select the resync range option (asynchronous) for selected pairs.

NOTE:

Resyncing suspended LDEV pairs within a Continuous Access XP LUSE pair is not supported.