67

NOTE:

After being set, options can be modified and canceled (see

Modifying parameters and

deleting consistency groups

” on page 72).

6.

Click Apply on the Continuous Access XP main pane to apply settings to the disk array.

Viewing consistency group status (CT Group Status)

Use the CT Group Status command to display consistency group status information.

1.

From the Consistency Group tree, click a consistency group mode that includes the consistency group

you want to display.

2.

From the Consistency Group list, click only one consistency group.

3.

Right-click, click CT Group Operation, and click CT Group Status. The CT Group Status pane appears.

Figure 39

CT Group Status pane

CT Group: Consistency group number of selected consistency group in the list.

This CU Type: Registering side (MCU or RCU) of consistency group.

CLPR: Number and name of the CLPR to which the volumes forming the pair belong.

S/N, ID: Serial number and SSID of CUs that are components of selected consistency group.

Port, G-ID, and LUN: Pairs in the connected CU that are in selected consistency group. The Group

column shows the host group name in parentheses. The LUN column shows the CU:LDEV in

parentheses. For LUs with more than one path, only the first path is listed.

NOTE:

If # is added to the end of the LDEV number, such as 00:3C#, the LDEV is an external

volume. For details about external volumes, see the HP StorageWorks External Storage XP user

guide.

MCU-RCU Path: Channel type: fibre or serial.

Time Out (Copy Pending): Maximum delay allowed for Continuous Access XP Async copy (see

Adding consistency groups (Add CT Group)

” on page 68).

Time Out (RCU Ready): Maximum delay allowed for re-establishing MCU-RCU communications

following MCU power-off (see

Adding consistency groups (Add CT Group)

” on page 68).

Previous button: Displays information about the consistency group before the current consistency

group.

Next button: Displays information about the consistency group after the current consistency group.

Refresh button: Refreshes displayed information.

Close button: Closes the CT Group Status pane.