Figure 30 rcu option pane, 30 rcu option pane – HP XP Continuous Access Software User Manual

Page 58

Advertising
background image

58

Continuous Access XP for the XP1024/XP128

Cancel button: Cancels settings made on the Add RCU pane, and closes the pane.

Figure 30

RCU Option pane

Use the RCU Option pane to set the options for the RCU.

Minimum Paths: Minimum number of paths required for each RCU connected to the current MCU. The

default is one. If you specify a number that is larger than the number of paths set on the Register RCU

pane or the number of paths falls below this number (for example, failed path), an error occurs. When

errors occur, the MCU suspends all affected Continuous Access XP (and any mainframe) pairs to

prevent remote copy operations from adversely affecting performance due to the inadequate number

of paths. If the MCU contains Continuous Access XP pairs, which contain critical data for disaster

recovery, set minimum number of paths to one, so Continuous Access XP operations continue even if

there is only one path to an RCU. If you need high performance at the MCU, set minimum number of

paths to two or more (up to eight per CU image), depending on number of pairs managed by the

MCU.

CAUTION:

If Continuous Access XP volume pairs are suspended because number of paths

dropped below this setting, the P-VOL fence-level pair option (see ”

Creating Continuous Access XP

volume pairs (Paircreate)

” on page 81) determines whether Continuous Access XP Synchronous

P-VOLs are fenced (that is, all write operations are rejected).

Maximum Initial Copy Activity: Number of concurrent initial copy operations: 4 Volumes or 16

Volumes. The default is 4 Volumes. Continuous Access XP initial copy activities can impact

performance of the main disk array, depending on amount of I/O activity and number of pairs

registered at one time. The setting of 4 Volumes limits impact of initial copy activities on disk array

performance. For example, if you set maximum initial copy activity to 4 Volumes and register five

Continuous Access XP pairs at one time, the MCU starts the first four pairs and will not start the fifth

pair until one of the first four pairs is synchronized (PAIR status). When you change the maximum

initial copy activity setting, the new setting applies to pairs created after the setting was changed, not

to existing pairs.

RIO MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH), which is the wait

time until data transfer from the MCU to RCU is complete. The RIO MIH time must be from 10 to 100

seconds. The default is 15 seconds. This setting is available for both serial and Fibre Channel

interfaces.

Path Blockade Watch: Time for monitoring blockade in Fibre Channel paths on the MCU side. The

path blockade watch must be from 0 to 45 seconds. The default is 40 seconds. This setting is

available for Fibre Channel interfaces only.

Cancel button: Cancels the registering RCU operation.

Set button: Sets the registering RCU operation with the option set on the RCU Option pane.

Advertising
This manual is related to the following products: